Can a shaver socket go next to a sink?
Recommended Locations In Bathroom For Shaver Socket Electrical shaver sockets must always be within a safe distance from the sink, bath or shower to avoid splashes. They must be located more than 3m from the edge of a bath or shower.
Can shaver socket go in Zone 1?
This is reinforced by Regulation 553.1. 5(ii), which does not allow a shaver socket-outlet conforming to BS 4573 to be installed in a bathroom. A socket-outlet without a transformer is prohibited within 3 m horizontally from the boundary of zone 1 of a location containing a bath or shower (Regulation 701.512.
Can I spur off a shaver socket?
A shaver socket must only supply one item. If there are two outlets they both must have their own isolated windings. They are type tested and it is not permissible to alter them and although it would seem safer to have the transformer remote from socket it is not allowed.
Are shaver sockets allowed in bathrooms?
In short, yes, a shaver socket should always be connected using an FCU (fused connection unit). Shaver sockets without transformers should not be used in a wet area such as a shower room or bathroom.
Does shaver socket need isolator?
The shaver socket does not need an isolator. 2. The fan need to be of a low voltage type, the isolator and transformer are fitted outside the bathroom, the isolator is normally placed above the door and often the transformer in the loft.
What is Zone 3 in a bathroom?
Zone 3. Zone 3 is anywhere outside zones 0, 1, and 2 (subject to specific limits) and where no water jet is likely to be used. No IP rating is required. However, if there is a likelihood of water jets being used for cleaning purposes in zones 1, 2 and 3, a fitting rated a minimum IP65 must be used.
Can you put a shaver socket in a bathroom?
Socket outlets should not be permitted in bathrooms or shower rooms (apart from shaver-supply units). This is unless they can be fitted a minimum distance of three metres from the bath or shower. Shaver sockets without transformers should not be used in a wet area such as a shower room or bathroom.
Can I fit a shaver socket in Zone 2?
Shaver sockets are a special case as we have mentioned above. Despite not being IPX4 rated they can be fitted in Zone 2 where direct spray or water contact is unlikely. See For more information see our how to fit a shave socket project here.
How do I know what voltage my shaver socket is rated at?
The front of a shaver supply unit is marked with the rated voltage (s) and with the symbol shown left. A degree of protection of at least IPX1 is provided by a shaver supply unit. A shaver socket-outlet without a transformer should conform to BS 4573 (Regulation 553.1.5 (ii) refers).
Can a shaver supply unit be installed in a bath?
A shaver supply unit complying with BS EN 61558-2-5 may be installed in zone 2 of a location containing a bath or shower (Regulation 701.512.3 refers). Neither the rated supply voltage nor rated output voltage of a shaver supply may exceed 250 V a.c.