BAXI ECOBLUE (COMBI & SYSTEM) Boiler Error/Fault Codes

Error Code Possible Fault
119 System Pressure Low (<0.5 bar)
125 Water circulation fault
127 Legionella Protection Temperature not reached
128 Loss of flame during operation

How do I reset my Baxi 128 Combi?

To reset the boiler, turn the selector switch to the R (Reset) position. Hold for at least 5 seconds and release. The fault code will be replaced with the boiler’s current temperature. At this point on a neon indicator boiler model, the flame failure light will stop flashing and will be replaced with the burner light.

What does E110 mean on a Baxi boiler?

E110 fault code is caused due to the limit stat being triggered generally due to the boiler overheating. This will protect major parts like a pump. General cause for this would be a blockage in the system or a faulty pump which will require the assistance of a gas engineer to repair the fault.

Where is the pressure gauge on a Baxi boiler?

When your boiler is not working, the pressure gauge should be set at about 1.5 bar. On the pressure gauge on the front of your boiler, the needle will be in the centre of the green triangle on the dial.

Why is my Baxi boiler not firing up?

A common culprit for this fault on Baxi boilers is a lack of pressure. If your system is set lower than 1.5 bar then it won’t operate correctly. Now, the quick fix is to top up the boiler pressure using the filling loop. And once you’ve topped up the boiler pressure, you’ll need to reset the boiler.

Why won’t my Baxi boiler fire up?

There could be lots of reasons why your Baxi boiler is not firing up. Firstly check the simple things like is there power to the boiler, are the controls set to on, is the room thermostat turned up. Then check if there are any error codes on the boiler and try resetting these if there are.

Why is my boiler on but no heating?

Things to check on your boiler If your boiler works but the radiators are not heating up, then likely cause could be a faulty boiler pump or your central heating controls. If your boiler works but the radiators are cold, check that the thermostat or timer is working correctly.

Why do I have to keep resetting my Baxi boiler?

If you find that you keep having to reset your boiler, it’s likely that there could be a fault with your heating system. This fault could eventually lead to a more serious issue such as a boiler breakdown, so it’s best to seek out a solution as soon as possible.

What pressure should my Baxi boiler be?

between 1.0 and 2.0 bar
The normal operating water pressure for your boiler and central heating system is between 1.0 and 2.0 bar. If the pressure drops below 1.0 bar, you need to repressurise it. If the pressure goes above 3.0 bar, you will see water coming from the pressure relief valve (usually on an outside wall).

What does Code 128 mean on a Baxi boiler?

According to Baxi, the 128 fault code relates to a loss of flame during operation. What causes my boiler to lose its flame? There are several potential issues that can cause your boiler to lose its flame during normal operation, including: A faulty gas valve, or incorrect adjustment

What are the error codes on my Baxi duo-tec&megaflo boiler?

Baxi Duo-Tec&Megaflo Boiler Error Codes Fault Code Possible Cause E131 Overheat lock out – this may follow a po E133 Gas supply fault E168 PCB lock out – may follow power supply p 110 Over heated – try bleeding your radiator

How do I find the fault code on my Baxi boiler?

When your Baxi locks out, an error code will be displayed on the LCD screen to help you identify what the issue is. The fault codes are listed in your boiler manual but it’s probably just easier to Google the error code and get the answer right here on the WarmZilla website.

What are the problems with the Baxi 105 he boiler?

Temporary error, self-reset. Ignition fault. Boiler has attempted to light 5 times and failed The Baxi 105 HE is a discontinued condensing combi boiler with an energy-efficiency rating of B. If you’re experiencing issues with your Baxi 105 HE boiler then, given its age, we would recommend upgrading it to a modern a-rated energy-efficient boiler.