What is an FT4 cable?

What is an FT4 cable?

The FT4 certification is one of the most popular as it has one of the toughest tests to pass, given the 70,000 BTU/hour flame. This certifications testing procedure has cables mounted on a vertical tray, which are exposed for 20 minutes to a 70,000 BTU/hour flame.

What is FT2 cable?

FT2: This is a horizontal flame test that is performed on finished cables. It is a minimum and mandatory requirement for flame testing flexible cords.

What is CAT6 FT4?

This cable connects all the hardware destinations on a Local Area Network (LAN). This 1000 feet long CAT6 Ethernet cable is ideal for setting up various computers in an office for example. Designed to be used with any standard cat6 RJ-45 connector on the market making it usable anywhere. (

Is CMG cable outdoor rated?

These are used for regular networking from room to room, as long as the cable does not need to pass through an air duct. CM/CMG are the most commonly used commercial grade communication cable. CMX is a residential grade cable….

Rating Usage
CMR,CL3R, CL2R All in-wall and riser applications; not permitted in plenums.

What is RW90 cable?

RW90 cables are primarily used for power distribution. They may be used in wet or dry locations, with. conductor temperatures not exceeding 90°C. Voltage rating for RW90 cable is 600V. Conductors: Stranded soft drawn bare copper, with Class B stranding per ASTM.

What is the difference between FT4 and FT6 cable?

FT4 Cables can be used in Non-Combustible buildings. Products passing the FT6 Horizontal Flame and Smoke Test are designated FT6 in the column where the trade number appears. This test is for cables which must pass a Horizontal Flame and Smoke Test in accordance with ANSI/NFPA Standard 262-1985 (UL-910).

What does CMG mean on wire?

commercial grade communication cable
Common Jacket Ratings CMR cables are riser cables. These are used for regular networking from room to room, as long as the cable does not need to pass through an air duct. CM/CMG are the most commonly used commercial grade communication cable. CMX is a residential grade cable.

What is FT4 certification and why is it important?

The FT4 certification is one of the most popular as it has one of the toughest tests to pass, given the 70,000 BTU/hour flame. This certifications testing procedure has cables mounted on a vertical tray, which are exposed for 20 minutes to a 70,000 BTU/hour flame. This test is identical to the IEEE 1202 flame test.

What is the ft1-ft6 CSA?

The FT1-FT6 certificates are a Canadian standard. The CSA is an extremely important North American approval that’s regularly getting modernized, on top of random check-ins and tests for all official distributors and manufacturers.

What is the FT6 certification process?

The testing procedure for the FT6 certification has a 25-foot Steiner Tunnel with intake and exhaust ducts that control the airflow. The cables are mounted within a tray on one level and sealed. Two circular burners are then mounted vertically at the tunnel’s intake end, just in front of the cable tray. Methane is burned along with 240 ft./min.

What is the FT5 horizontal flame test?

The FT5 horizontal flame test is used for power cables and portable cords like the SHD-GC for use in surface or underground mining applications. The testing procedure for the FT5 certification involves three one-meter samples that are set up horizontally.